Flat Submersible Cables

  • About the Product
  • Advantages
  • Technical Details

Flat Cable

AVOCAB manufactures optimum quality flat submersible cables keeping the international and national norms of quality and testing into consideration. Avocab flat submersible cables provide strong resistance and safe transmission of power under indefinite submersion in water.

The biggest advantages of using a submersible cable is that it is designed to work effectively even in hostile and demanding work environments. The cable has also been made specifically to offer a high level of safety and reliability. It is found to be very resilient to abrasion, moisture and grease.

Size (mm2)

Conductor Construction No./Nom. Dia. ( No./mm)

Max Conductor Resistance At 20 °C ( Ohm/Km)

Insulation Thickness (Nom.) (mm)

Total Thickness Of Double Sheath (Nom.) (mm)

Overall Diameter (Approx.) (mm)

1.5

30/0.25

13.3

0.6

1.6

9.9

2.5

50/0.25

7.98

0.7

1.6

11.5

4

56/0.3

4.95

0.8

1.6

13.5

6

84/0.3

3.30

0.8

1.8

15.0

10

140/0.3

1.91

1.0

2.0

18.6

16

226/0.3

1.21

1.0

2.2

21.8

25

354/0.3

0.780

1.2

2.4

25.9

35

495/0.3

0.554

1.2

2.6

28.8

50

703/0.3

0.386

1.4

2.6

33.6

70

360/0.5

0.272

1.4

2.8

38.4

95

475/0.5

0.206

1.6

2.8

42.6

3 CORE FLAT SUBMERSIIBLE CABLES AS PER IS: 694 -1990 WITH ISI MARK

Conductor

Insulation

Sheath

Overall Dimension

Conductor  Resistance@20°C ( Max. ) Ohms/km.

Current Caring Capacity@ 40°C Amps

Area Sq.mmm

Thickness (Nom) mm

Thickness (Nom) mm

Thickness (Nom)m m

Width (Approx) ‘W’ mm

Height (Approx) ‘H’ mm

1.5

22/0.30*

0.6

0.9

10.30

4.9

12.10

14

2.5

36/0.30*

0.7

1.0

12.60

5.8

7.41

18

4.0

56/0.30*

0.8

1.0

14.80

6.6

4.95

26

Note: The Strand diameter is nominal. However, construction of conductor is designed to satisfy The requirements of conductor resistance as per IS: 8130-1984. *As per Conductor Class 2 of IS: 8130-1984 **As per Conductor Class 5 of IS 8130-1984

3 CORE FLAT  CABLE GENERALLY CONFORMING TO IS: 694 -1990

Conductor

Insulation

Sheath

Overall Dimension

Conductor  Resistance@20°C ( Max. ) Ohms/km.

Current Caring Capacity@ 40°C  Amps

Area Sq.mmm

No .of Strands/ Dia. mm

Thickness (Nom) mm

Thickness (Nom) Mm

Width (Approx) ‘W’ mm

Height (Approx) ‘H’ mm

6.0

84/0.30

0.8

1.15

16.50

7.40

3.30

31

10.0

140/0.30

1.0

1.40

21.00

9.25

1.91

42

16.0

224/0.30

1.0

1.40

24.50

10.70

1.21

57

25.0

354/0.30

1.2

2.00

30.60

13.50

0.780

72

35.0

495/0.30

1.2

2.00

34.40

14.70

0.554

90

50.0

703/0.30

1.4

2.20

41.20

17.20

0.386

115

70.0

360/0.30

1.4

2.20

46.60

19.00

0.272

143

95.0

475/0.30

1.6

2.40

53.00

21.40

0.206

165

Note: The number of wires and strand diameter will be such as to satisfy the requirements of conductor resistance as per IS: 8130 -1984.

SELECTION GUIDE FOR 3 CORE FLAT  CABLES CABLE SELECTION CHART AT 40° C 415 V (WITH DOL STARTER)

SUBMERSIBLE MOTORS

Size Of Cable in Sq.MM. at different Length in Mtrs.

H.P.

FULL LOAD CURRENT Amps.

10

20

30

40

50

60

70

80

90

100

110

128

140

180

200

5

7.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.5

2.5

4

4

7.5

11

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.5

2.5

2.5

2.5

4

4

4

6

10

15

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

4

4

4

4

6

10

12.5

19

2.5

2.5

2.5

2.5

2.5

2.5

2.5

4

4

4

4

6

6

10

10

15

22.5

4

4

4

4

4

4

4

4

4

6

6

6

10

10

10

17.5

26

4

4

4

4

4

4

4

4

6

6

6

10

10

10

16

20

28.4

6

6

6

6

6

6

6

6

6

6

6

10

10

10

16

25

35.6

10

10

10

10

10

10

10

10

10

10

10

10

10

16

16

30

42.3

10

10

10

10

10

10

10

10

10

10

10

10

10

16

25

35

50.4

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

40

58.1

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

45

62.1

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

50

67.5

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

55

73.8

35

35

35

35

35

35

35

35

35

35

35

35

35

35

35

60

81.0

35

35

35

35

35

35

35

35

35

35

35

35

35

35

35

65

87.3

35

35

35

35

35

35

35

35

35

35

35

35

35

35

35

70

93.6

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

75

100.8

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

80

108.0

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

CABLE SELECTION CHART AT 40° C 415 V (WITH  STAR –DELTA STARTER –DOUBLE CABLE)

SUBMERSIBLE MOTORS

Size Of Cable in Sq.MM. at different Length in Mtrs.

H.P.

FULL LOAD CURRENT Amps.

10

20

30

40

50

60

70

80

90

100

110

128

140

180

200

5

7.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

7.5

11

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.6

2.5

4

4

10

15

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.5

2.5

2.5

2.5

4

4

4

6

12.5

19

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.5

2.5

2.5

2.5

4

4

4

6

15

22.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

4

4

4

4

4

6

17.5

26

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

4

4

4

4

6

6

20

28.4

2.5

2.5

2.5

2.5

2.5

2.5

2.5

4

4

4

4

6

6

10

10

25

35.6

4

4

4

4

4

4

4

4

4

4

6

6

10

10

10

30

42.3

4

4

4

4

4

4

4

4

4

6

6

10

10

10

10

35

50.4

6

6

6

6

6

6

6

6

6

6

6

10

10

10

16

40

58.1

10

10

10

10

10

10

10

10

10

10

10

10

10

16

16

45

62.1

10

10

10

10

10

10

10

10

10

10

10

10

10

16

16

50

67.5

10

10

10

10

10

10

10

10

10

10

10

10

16

16

16

55

73.8

10

10

10

10

10

10

10

10

10

10

10

10

16

16

16

60

81.0

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

65

87.3

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

70

93.6

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

75

100.8

16

16

16

16

16

16

16

16

16

16

16

16

16

25

25

80

108.0

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25