We introduce ourselves as a leading manufacturer of Wires & Cables in India. With a proven track record of more than three decades, we are an ISO-9001:2000 Certified Company With a strong presence in our Industry. AVOCAB manufactures optimum quality housewires and flexible cables. Our Well established manufacturing set up is situated in the industrial belt of Chattral, Gujarat and our brand name of “ AVOCAB’’ is a household name across the state and beyond . FRLS PVC Insulated Wires, In case of Fire, reduce the Toxic Smoke Generation compared to normal PVC Insulated Wires. In modern Houses & Offices No. of Gadgets are used which increases Chances of fire due to overload & Short Circuit. Generally Fire is attributed to electric short circuit hence this advisable to use/Install low & non Toxic Smoke generating (FRLS) Wires & cables. AVOCAB FRLS Wires & Cables have these enhanced properties of PVC Insulation.
High quality standards are in – built into every AVOCAB products including house wires and flexible cables. Rigid tests and check at every stage, from raw material through manufacturing stages and finally up to the finished product ensure that AVOCAB cables meet National Standards, and consumer approval. We Have FRLS Testing Facility as per International IEC Norms and the housewires and flexible cables are also tested as per the norms of the industry.
Nominal area of conductor | Number Nom. Dia. Of Wires | Thickness Of Insulation (Nom.) |
Approx Overall Diameter | Current Carrying Capacity* | Resistance (Max.) Per Km. @20° C |
Sq.mm | mm. | mm. | Mm. | Amps. | Amps. |
0.75 | 24/0.20 | 0.6 | 2.5 | 7 | 26.00 |
1.0 | 14/0.30 | 0.7 | 2.8 | 12 | 18.10 |
1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 12.10 |
2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 7.41 |
4.0 | 56/0.30 | 0.8 | 4.4 | 29 | 4.95 |
6.0 | 84/0.30 | 0.8 | 5.2 | 37 | 3.30 |
Test | Specification | Specified Value |
Critical Oxygen Index | ASTM – D2863 -77 | Minimum 29 % |
Temperature Index | ASTM – D 2863 – 77 | Minimum 250°C |
Smoke density | ASTM – D 2843 – 77 | Minimum 60 % |
Halogen Acid Gas Eval. | IEC 754 -1 | Minimum 20 % |
Swedish Chimney | SS : 424-14-75-CLASS F3 | Minimum 300mm from top end |
The conductors are drawn from bright electrolytic grade copper and annealed conductors are bunched together.
Bunched conductors are insulated with specially formulated, in –house developed FPLS PVC Compound With high Insulation resistance values. The insulation process is carried out on modern high speed extrusion lines with high accuracy, ensuring consistency in performance.
Industrial Power Cables up to 33 KV as per IS -1554(part I & II) & IS 7098 (part I & II)
FR PVC/ HRPVC/FRLS Insulated up to 10 sq. mm in all colours Flexible/Stranded/ Solid type Copper Conductor
Section | Download |
HOUSE WIRE & FLEXIBLE CABLE | ![]() |
Single core multi-stranded copper conductor, FR PVC insulated wires with excellent flame retardant properties.
Single core multi-standard copper conductor, FRLS PVC insulated wire with excellent flame retardant, low smoke, and Low halogen properties.
Single core multistandard copper conductor, ZHFR insulated wire with excellent flame retardant low smoke properties having Rohs compliances zero halogen