Flat Submersible Cables

About the Product

AVOCAB manufactures optimum quality flat submersible cables keeping the international and national norms of quality and testing into consideration. Avocab flat submersible cables provide strong resistance and safe transmission of power under indefinite submersion in water.

The biggest advantages of using a submersible cable is that it is designed to work effectively even in hostile and demanding work environments. The cable has also been made specifically to offer a high level of safety and reliability. It is found to be very resilient to abrasion, moisture and grease.

Advantages

The biggest advantages of using a submersible cable is that it is designed to work effectively even in hostile and demanding work environments. The cable has also been made specifically to offer a high level of safety and reliability. It is found to be very resilient to abrasion, moisture and grease.


Technical Details

SINGLE CORE WIRES IN VOLTAGE GRADE 1100 V (FR/FRLS)

Size (mm2) Conductor Construction No./Nom. Dia. ( No./mm) Max Conductor Resistance At 20 °C ( Ohm/Km) Insulation Thickness (Nom.) (mm) Total Thickness Of Double Sheath (Nom.) (mm) Overall Diameter (Approx.) (mm)
1.5 30/0.25 13.3 0.6 1.6 9.9
2.5 50/0.25 7.98 0.7 1.6 11.5
4 56/0.3 4.95 0.8 1.6 13.5
6 84/0.3 3.30 0.8 1.8 15.0
10 140/0.3 1.91 1.0 2.0 18.6
16 226/0.3 1.21 1.0 2.2 21.8
25 354/0.3 0.780 1.2 2.4 25.9
35 495/0.3 0.554 1.2 2.6 28.8
50 703/0.3 0.386 1.4 2.6 33.6
70 360/0.5 0.272 1.4 2.8 38.4
95 475/0.5 0.206 1.6 2.8 42.6

3 CORE FLAT SUBMERSIIBLE CABLES AS PER IS: 694 -1990 WITH ISI MARK

Conductor Insulation Sheath Overall Dimension Conductor  Resistance @20°C ( Max. ) Ohms/km. Current Caring Capacity@ 40°C Amps
Area Sq.mmm Thickness (Nom) mm Thickness (Nom) mm Thickness (Nom)m m Width (Approx) ‘W’ mm Height (Approx) ‘H’ mm
1.5 22/0.30* 0.6 0.9 10.30 4.9 12.10 14
2.5 36/0.30* 0.7 1.0 12.60 5.8 7.41 18
4.0 56/0.30* 0.8 1.0 14.80 6.6 4.95 26

Note: The Strand diameter is nominal. However, construction of conductor is designed to satisfy The requirements of conductor resistance as per IS: 8130-1984. *As per Conductor Class 2 of IS: 8130-1984 **As per Conductor Class 5 of IS 8130-1984

3 CORE FLAT CABLE GENERALLY CONFORMING TO IS: 694 -1990

Conductor Insulation Sheath Overall Dimension Conductor Resistance
@ 20
°C (Max. ) Ohms/km.
Current Caring Capacity@ 40°C  Amps
Area Sq.mmm No .of Strands/ Dia. mm Thickness (Nom) mm Thickness (Nom) Mm Width (Approx) ‘W’ mm Height (Approx) ‘H’ mm
6.0 84/0.30 0.8 1.15 16.50 7.40 3.30 31
10.0 140/0.30 1.0 1.40 21.00 9.25 1.91 42
16.0 224/0.30 1.0 1.40 24.50 10.70 1.21 57
25.0 354/0.30 1.2 2.00 30.60 13.50 0.780 72
35.0 495/0.30 1.2 2.00 34.40 14.70 0.554 90
50.0 703/0.30 1.4 2.20 41.20 17.20 0.386 115
70.0 360/0.30 1.4 2.20 46.60 19.00 0.272 143
95.0 475/0.30 1.6 2.40 53.00 21.40 0.206 165

Note: The number of wires and strand diameter will be such as to satisfy the requirements of conductor resistance as per IS: 8130 -1984.

SELECTION GUIDE FOR 3 CORE FLAT CABLES CABLE SELECTION CHART AT 40° C 415 V (WITH DOL STARTER)

SUBMERSIBLE MOTORS Size Of Cable in Sq.MM. at different Length in Mtrs.
H.P. FULL LOAD CURRENT Amps. 10 20 30 40 50 60 70 80 90 100 110 128 140 180 200
5 7.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 4 4
7.5 11 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 4 6
10 15 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 10
12.5 19 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6 10 10
15 22.5 4 4 4 4 4 4 4 4 4 6 6 6 10 10 10
17.5 26 4 4 4 4 4 4 4 4 6 6 6 10 10 10 16
20 28.4 6 6 6 6 6 6 6 6 6 6 6 10 10 10 16
25 35.6 10 10 10 10 10 10 10 10 10 10 10 10 10 16 16
30 42.3 10 10 10 10 10 10 10 10 10 10 10 10 10 16 25
35 50.4 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
40 58.1 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
45 62.1 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25
50 67.5 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25
55 73.8 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35
60 81.0 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35
65 87.3 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35
70 93.6 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
75 100.8 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
80 108.0 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50

CABLE SELECTION CHART AT 40° C 415 V (WITH STAR –DELTA STARTER –DOUBLE CABLE)

CABLE SELECTION CHART AT 40° C 415 V (WITH  STAR –DELTA STARTER –DOUBLE CABLE)
SUBMERSIBLE MOTORS Size Of Cable in Sq.MM. at different Length in Mtrs.
H.P. FULL LOAD CURRENT Amps. 10 20 30 40 50 60 70 80 90 100 110 128 140 180 200
5 7.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
7.5 11 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.6 2.5 4 4
10 15 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 4 6
12.5 19 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 4 4 4 6
15 22.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 6
17.5 26 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6
20 28.4 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6 6 10 10
25 35.6 4 4 4 4 4 4 4 4 4 4 6 6 10 10 10
30 42.3 4 4 4 4 4 4 4 4 4 6 6 10 10 10 10
35 50.4 6 6 6 6 6 6 6 6 6 6 6 10 10 10 16
40 58.1 10 10 10 10 10 10 10 10 10 10 10 10 10 16 16
45 62.1 10 10 10 10 10 10 10 10 10 10 10 10 10 16 16
50 67.5 10 10 10 10 10 10 10 10 10 10 10 10 16 16 16
55 73.8 10 10 10 10 10 10 10 10 10 10 10 10 16 16 16
60 81.0 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
65 87.3 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
70 93.6 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
75 100.8 16 16 16 16 16 16 16 16 16 16 16 16 16 25 25
80 108.0 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25

Copyright ©2023 Chandresh Cables Limited All Rights Reserved.   |   Powered by: #1 Vinayak InfoSoft